PRICES include / exclude VAT
Homepage>IEEE Standards>29 ELECTRICAL ENGINEERING>29.220 Galvanic cells and batteries>29.220.20 Acid secondary cells and batteries>IEEE 535-2013 - IEEE Standard for Qualification of Class 1E Vented Lead Acid Storage Batteries for Nuclear Power Generating Stations
Sponsored link
Released: 22.11.2013

IEEE 535-2013 - IEEE Standard for Qualification of Class 1E Vented Lead Acid Storage Batteries for Nuclear Power Generating Stations

IEEE Standard for Qualification of Class 1E Vented Lead Acid Storage Batteries for Nuclear Power Generating Stations

Format
Availability
Price and currency
English PDF Redline
Immediate download
72.71 EUR
English PDF Redline
Immediate download
66.10 EUR
English PDF
Immediate download
55.60 EUR
English PDF
Immediate download
50.54 EUR
English Hardcopy
In stock
71.64 EUR
Standard number:IEEE 535-2013
Released:22.11.2013
ISBN:978-0-7381-8723-5
Pages:29
Status:Active
Language:English
DESCRIPTION

IEEE 535-2013

This standard describes qualification methods for Class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary containment. Qualifications required by IEEE Std 308(TM)can be demonstrated by using the procedures in this standard in accordance with IEEE Std 323(TM). Application of batteries in nuclear power generating stations can be divided into two sections: duty cycles equal to or less than 8 h and duty cycles greater than 8 h. This standard provides a process to demonstrate qualification for both applications. This standard is based on the user demonstrating that the predominant failure mechanism is positive plate grid corrosion. The following technologies have been demonstrated to meet this criterion for full float service: a) Lead-calcium b) Lead-antimony c) Lead-selenium low antimony To apply this standard to vented lead-acid technologies other than those listed above, the user is required to demonstrate the following for full float service: a) The predominant failure mechanism is positive plate grid corrosion b) The accelerated aging factors shall be determined in 8.3.2 e) Battery sizing, maintenance, capacity testing, installation, charging equipment, and consideration of other type batteries are beyond the scope of this standard.

This document will not contain a purpose clause.

Revision Standard - Superseded. Qualification methods for Class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary containment are described in this standard. Qualifications required by IEEE Std 308(TM) can be demonstrated by using the procedures in this standard in accordance with IEEE Std 323(TM). The application of batteries in nuclear power generating stations can be divided into two sections: duty cycles equal to or less than 8 h and duty cycles greater than 8 h. A process to demonstrate qualifications for both applications is provided in this standard.