PRICES include / exclude VAT
Sponsored link
Released: 30.01.2015
IEEE C37.114-2014 - IEEE Guide for Determining Fault Location on AC Transmission and Distribution Lines
IEEE Guide for Determining Fault Location on AC Transmission and Distribution Lines
Format
Availability
Price and currency
English PDF Redline
Immediate download
193.53 EUR
English PDF
Immediate download
137.93 EUR
English Hardcopy
In stock
173.21 EUR
Standard number: | IEEE C37.114-2014 |
Released: | 30.01.2015 |
ISBN: | 978-0-7381-9421-9 |
Pages: | 76 |
Status: | Active |
Language: | English |
DESCRIPTION
IEEE C37.114-2014
This guide outlines the techniques and application considerations for determining the location of a fault on ac transmission and distribution lines. This document reviews traditional approaches and the primary measurement techniques used in modern devices: one- and two-terminal impedance-based methods, synchronized sampling methods and traveling-wave methods. Application considerations include: two-and three-terminal lines, series-compensated lines, parallel lines, untransposed lines, tapped lines, underground cables, fault resistance effects, and other power system conditions, including those unique to distribution systems.The guide assists power system engineers and operators in applying fault-locating techniques on their systems. Users learn the strengths and limitations of fault location data and when further analysis is required using additional methods and when more data must be gathereed. This guide assists in fault location and therefore faster restoration of power systems through improved understanding of fault-locating techniques.
Revision Standard - Active. Electrical faults on transmission and distribution lines are detected and isolated by system protective devices. Once the fault has been cleared, outage times can be reduced if the location of the fault can be determined more quickly. The techniques and application considerations for determining the location of a fault on ac transmission and distribution lines are outlined in this guide. Traditional approaches and the primary measurement techniques used in modern devices are reviewed: one- and two-terminal impedance-based methods and traveling-wave methods. Application considerations include: two- and three-terminal lines, series-compensated lines, parallel lines, untransposed lines, underground cables, fault resistance effects, and other power system conditions, including those unique to distribution systems.