PRICES include / exclude VAT
Sponsored link
Released: 10.06.1994
IEEE C37.20.2-1993 - IEEE Standard for Metal-Clad and Station-Type Cubicle Switchgear
IEEE Standard for Metal-Clad and Station-Type Cubicle Switchgear
Format
Availability
Price and currency
English PDF
Immediate download
152.90 EUR
Standard number: | IEEE C37.20.2-1993 |
Released: | 10.06.1994 |
ISBN: | 978-0-7381-1054-7 |
Pages: | 64 |
Status: | Active |
Language: | English |
DESCRIPTION
IEEE C37.20.2-1993
This standard covers metal-clad and station-type cubicle switchgear containing, but not limited to, such devices as power circuit breakers; other interrupting devices; switches; control; instrumentation and metering; and protective and regulating equipment. It includes, but is not specifically limited to, equipment for the control and protection of apparatus used for power generation, conversion, and transmission and distribution. This standard is concerned with enclosed, rather than open, indoor and outdoor switchgear assemblies rated above 1000 V. It applies to equipment that is part of primary and secondary unit substations. It does not include gas insulated substation equipments. In this standard metal-clad switchgear shall be called MC switchgear, and station-type cubicle switchgear shall be called SC switchgear. Whenever the data covers both types of equipments, they shall be called ME switchgear.Revision Standard - Superseded. Metal-enclosed medium voltage switchgear (ME), which can contain either drawout electrically operated circuit breakers or stationary electrically operated circuit breakers in individual three-pole grounded metal compartments, is covered. Further, metal-clad switchgear (MC) is compartmentalized to isolate all components such as instrumentation, main bus, and both incoming and outgoing connections with grounded metal barriers. Rated maximum voltage levels for metal-clad switchgear (MC) range from 5 kV through 38 kV with main bus continuous current ratings of 1200 A, 2000 A, and 3000 A. Rated maximum voltage levels for station-type cubicle switchgear (SC) range from 15.5 kV through 72.5 kV with main bus continuous current ratings of 2000 A, 3000 A, 4000 A, and 5000 A. ME switchgear also contains associated control, instruments, metering, relaying, protective, and regulating devices as necessary. Service conditions, ratings, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are discussed.