PRICES include / exclude VAT
Homepage>IEEE Standards>29 ELECTRICAL ENGINEERING>29.130 Switchgear and controlgear>29.130.10 High voltage switchgear and controlgear>IEEE C37.20.6-2007 - IEEE Standard for 4.76 kV to 38 kV Rated Ground and Test Devices Used in Enclosures
Released: 18.03.2008

IEEE C37.20.6-2007 - IEEE Standard for 4.76 kV to 38 kV Rated Ground and Test Devices Used in Enclosures

IEEE Standard for 4.76 kV to 38 kV Rated Ground and Test Devices Used in Enclosures

Format
Availability
Price and currency
English PDF
Immediate download
111.20 EUR
Standard number:IEEE C37.20.6-2007
Released:18.03.2008
ISBN:978-0-7381-5381-0
Pages:30
Status:Active
Language:English
DESCRIPTION

IEEE C37.20.6-2007

This standard covers drawout-type, indoor, medium-voltage ground and test (G&T) devices for use in drawout metal-clad switchgear rated 4.76 kV through 38 kV as described in IEEE Std C37.20.2-1999.1 Four G&T device types are generally supplied for temporary circuit maintenance procedures for insertion in place of the circuit breaker as follows: a) Simple manual devices b) Complex manual devices c) Simple electrical devices d) Complex electrical devices There may be more complicated G&T devices that may include current and/or voltage transformers, glowtubes,or other accessory components. These more complex devices are not covered by this standard. Due to their complexity, additional testing and interlocking are required, and manufacturers should be consulted for the availability and ratings of these types of devices.

Although G&T devices have been used as accessory devices in metal-clad switchgear for decades, they were not addressed in the standards until IEEE Std C37.20.6(TM)-1997 was approved. This is because they are specialized accessory devices, designed and tested in accordance with applicable sections of circuit breaker standards, and based on user-unique operational requirements. This revised standard complements IEEE Std C37.20.2-1999 and addresses the more common G&T device types. This standard also clarifies that G&T devices are not required to have the interrupting and continuous current ratings of the circuit breakers they may temporarily replace for the purpose of grounding and testing medium-voltage circuits.

Revision Standard - Superseded. Drawout-type ground and test devices for use in medium-voltage metal-clad switchgear rated 4.76 kV through 38 kV are covered. The description, design, and testing of these accessory devices that are inserted in place of drawout circuit breakers for the purpose of grounding and testing are also covered.