Homepage>IEEE Standards>29 ELECTRICAL ENGINEERING>29.180 Transformers. Reactors>IEEE C57.12.34-2022 - IEEE Standard Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 10 MVA and Smaller; High-Voltage, 34.5 kV Nominal System Voltage and Below; Low-Voltage, 15 kV Nominal System Voltage and Below
Released: 21.12.2022

IEEE C57.12.34-2022 - IEEE Standard Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 10 MVA and Smaller; High-Voltage, 34.5 kV Nominal System Voltage and Below; Low-Voltage, 15 kV Nominal System Voltage and Below

IEEE Standard Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 10 MVA and Smaller; High-Voltage, 34.5 kV Nominal System Voltage and Below; Low-Voltage, 15 kV Nominal System Voltage and Below

Format
Availability
Price and currency
English PDF
Immediate download
75.82 EUR
English Hardcopy
In stock
94.28 EUR
Standard number:IEEE C57.12.34-2022
Released:21.12.2022
ISBN:978-1-5044-9174-7
Pages:56
Status:Active
Language:English
DESCRIPTION

IEEE C57.12.34-2022

This standard covers certain electrical, dimensional, and mechanical characteristics and takes into consideration certain safety features of three-phase, 60 Hz, liquid-immersed, self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated 10 MVA and smaller, with the high-voltage limit of 34.5 kV system nominal voltage and below, and with low-voltage limit of 15 kV system nominal voltage and below. These transformers are generally used for step-down purposes from an underground primary cable supply. This standard covers the connector, bushing, and terminal arrangements for radial or loop-feed systems. Either certain minimum dimensions or certain specific dimensions shall be specified. This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.

This standard is intended for use as a basis for determining performance, interchangeability, and safety of the equipment covered, and to assist in the proper selection of such equipment.

Revision Standard - Active. Certain electrical, dimensional, and mechanical characteristics are set forth, as well as certain safety features of three-phase, 60 Hz, liquid-immersed, self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated 10 MVA and smaller, with the high-voltage limit of 34.5 kV nominal system voltage and below, and with low-voltage limit of 15 kV nominal system voltage and below. This standard covers the connector, bushing, and terminal arrangements for radial or loop-feed systems. This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.