IEEE C57.152-2013 - IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors

IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors

Format
Availability
Price and currency
English PDF
Immediate download
193.53 EUR
English PDF
Immediate download
185.65 EUR
English Hardcopy
In stock
230.95 EUR
Withdraw:21.03.2024
Standard number:IEEE C57.152-2013
Released:21.06.2013
ISBN:978-0-7381-8369-5
Pages:121
Status:Active
Status:Inactive
Language:English
DESCRIPTION

IEEE C57.152-2013

This guide describes diagnostic field tests and measurements that are performed on fluid-filled power transformers and regulators. Whenever possible, shunt reactors are treated in a similar manner to transformers. The tests are presented systematically in categories depending on the subsystem of the unit being examined. A diagnostic chart is included as an aid to identifying the various subsystems. Additional information is provided regarding specialized test and measuring techniques. Interpretive discussions are also included in several areas to provide additional insight on the particular test or to provide guidance on acceptance criteria. These discussions are based on the authors’ judgment of accepted practice. It should be noted that the results of several types of tests should be interpreted together to diagnose a problem. Manufacturers’ acceptance criteria and other standards in the IEEE C57™ series take precedence over the content of this guide.

This guide will not include a Purpose statement.

Revision Standard - Inactive-Reserved. Diagnostic tests and measurements that are performed in the field on fluid-filled power transformers and regulators are described. Whenever possible, shunt reactors are treated in a similar manner to transformers. Tests are presented systematically in categories depending on the subsystem of the unit being examined. A diagnostic chart is included as an aid to identify the various subsystems. Additional information is provided regarding specialized test and measuring techniques. Interpretive discussions are also included in several areas to provide additional insight on the particular test or to provide guidance on acceptance criteria. These discussions are based on the authors' judgment of accepted practice. It should be noted that the results of several types of tests should be interpreted together to diagnose a problem. Manufacturers' acceptance criteria should also be consulted as it may take precedence over the criteria in this guide.