IEEE C57.16-2011 - IEEE Standard for Requirements, Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors

IEEE Standard for Requirements, Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors

Format
Availability
Price and currency
English PDF Redline
Immediate download
244.85 EUR
English PDF
Immediate download
177.49 EUR
English Hardcopy
In stock
217.05 EUR
Standard number:IEEE C57.16-2011
Released:02.02.2012
ISBN:978-0-7381-7143-2
Pages:127
Status:Active
Language:English
DESCRIPTION

IEEE C57.16-2011

This standard applies to series-connected dry-type air-core single-phase and three-phase outdoor or indoor reactors of distribution and transmission voltage class that are connected in the power system to control power flow under steady-state conditions and/or limit fault current under short-circuit conditions. Dry-type air-core reactors covered by this standard are self-cooled by natural air convection. With some restrictions, this standard is applicable to filter reactors, shunt capacitor reactors (used with shunt capacitor banks), and discharge current-limiting reactors (used with series capacitor banks). Annex A, Annex B, and Annex C are included to provide guidance. This standard does not apply to devices such as a) Shunt reactors (see IEEE Std C57.21(TM)-2008) b) Arc suppression coils c) Neutral grounding devices (see IEEE Std 32(TM)-1972 [B21]) d) Line resonant reactors e) High-voltage direct current (HVDC) smoothing reactors (IEEE Std 1277(TM)-2010 [B23]) f) Forced cooled reactors g) Line traps and radio interference (RI) filter reactors (ANSI C93.3-1995)

The purpose of this standard is to define the requirements and test code for series-connected dry-type aircore reactors and, with some restrictions, filter reactors, shunt capacitor reactors, and discharge currentlimiting reactors.

Revision Standard - Active. Recommendations are given for reactors intended for series connection, in both transmission and distribution systems, to control power flow under steady-state conditions and/or limit fault current under short-circuit conditions. Dry-type air-core reactors covered by this standard are self-cooled by natural air convection. With some restrictions, other reactors, including filter reactors, shunt capacitor reactors (used with shunt capacitor banks), and discharge current-limiting reactors (used with series capacitor banks) are also covered.