PRICES include / exclude VAT
Homepage>IEEE Standards>29 ELECTRICAL ENGINEERING>29.240 Power transmission and distribution networks>29.240.10 Substations. Surge arresters>IEEE C62.22-1997 - IEEE Guide for Application of Metal-Oxide Surge Arresters for Alternating-Current Systems
Sponsored link
Released: 17.07.1998

IEEE C62.22-1997 - IEEE Guide for Application of Metal-Oxide Surge Arresters for Alternating-Current Systems

IEEE Guide for Application of Metal-Oxide Surge Arresters for Alternating-Current Systems

Format
Availability
Price and currency
English PDF
Immediate download
176.42 EUR
Standard number:IEEE C62.22-1997
Released:17.07.1998
ISBN:978-0-7381-0938-1
Pages:104
Status:Active
Language:English
DESCRIPTION

IEEE C62.22-1997

This guide covers the application of metal-oxide surge arresters (see IEEE Std C62.11-1993 ) to safeguard electric power equipment against the hazards of abnormally high voltage surges of various origins. Such overvoltages may cause flashovers and serious damage to equipment and thereby jeopardize the supply of power to users. It is essential to prevent this by the proper coordination of surge-protective devices with the insulation strength of the protected equipment. This application guide does not cover the application of low-voltage surge protective devices below 1000 V ac. However, it references these devices when applied to the secondary of a transformer since they are part of the transformer protection. The subject is broad, with many ramifications, and it requires a volume of considerable bulk to explain all possible cases in detail. Clause of this guide covers the basic cases for stations used to supply and switch electric power transmission, subtransmission, or distribution feeders. Information is included in Clause on application of arresters for protection of overhead and underground distribution systems, all distribution transformers, and other electric distribution equipment. Step-by-step directions toward proper solutions for various applications are provided. In many cases, the prescribed steps are adequate. More complex and special situations requiring study by experienced engineers are described, but specific solutions may not be given. These procedures are based on theoretical studies, test results, and experience.

The purpose of this annex is to provide a relatively simple method for calculating maximum allowable separation distances between surge arresters and equipment to be protected.

Revision Standard - Superseded. The application of metal-oxide surge arresters to safeguard electric power equipment against the hazards of abnormally high voltage surges of various origins is covered. Step-by- step directions toward proper solutions of various applications are provided. In many cases, the prescribed steps are adequate. More complex and special solutions requiring study by experi- enced engineers are described, but specific solutions are not always given. The procedures are based on theoretical studies, test results, and experience.