PRICES include / exclude VAT
Homepage>IEEE Standards>29 ELECTRICAL ENGINEERING>29.180 Transformers. Reactors>IEEE C62.69a-2017 - IEEE Standard for the Surge Parameters of Isolating Transformers used in Networking Devices and Equipment - Amendment 1: Addition of Saturated Core Secondary Winding Parameters
Sponsored link
Released: 14.07.2017

IEEE C62.69a-2017 - IEEE Standard for the Surge Parameters of Isolating Transformers used in Networking Devices and Equipment - Amendment 1: Addition of Saturated Core Secondary Winding Parameters

IEEE Standard for the Surge Parameters of Isolating Transformers used in Networking Devices and Equipment - Amendment 1: Addition of Saturated Core Secondary Winding Parameters

Format
Availability
Price and currency
English PDF
Immediate download
56.67 EUR
English Hardcopy
In stock
71.64 EUR
Standard number:IEEE C62.69a-2017
Released:14.07.2017
ISBN:978-1-5044-3919-0
Pages:15
Status:Active
Language:English
DESCRIPTION

IEEE C62.69a-2017

This standard sets terms, test methods, test circuits, measurement procedures, and preferred result values for the surge parameters of isolating transformers used in networking devices and equipment. Three types of isolating transformer are considered: mains low frequency power, high frequency power (switching mode power supplies) and signal (e.g., Ethernet data). The surge parameters of the isolating transformer insulation barrier covered by this standard are as follows: - Rated impulse voltage - Input winding to output winding capacitance - Insulation resistance Additional parameters for signal isolating transformers are as follows: - Core saturation voltage-time product - Rated input winding rms current for a given temperature rise This standard does not cover the transformer parameters required to help ensure appropriate operation on the service (e.g., signal transformer return loss).

The main purpose of this standard is to define a series of transformer impulse withstand voltage ratings that are higher than those of IEEE Std 802.3(TM) [B6] with the intent to improve transformer insulation performance in uncontrolled environments. In the interests of International standardization the voltage values used are harmonized with the series defined in IEC 60664-1[B7] for low-voltage equipment insulation coordination. This IEEE standard is applicable to home networking installations, which are typically uncontrolled environments, where the surge voltage levels and the corresponding required transformer impulse withstand voltages can be higher than the LAN A controlled environment as defined by IEEE Std 802.3(TM) [B6].

Amendment Standard - Active. Added in this amendment is a new sub-clause, 4.5 Saturated core secondary winding parameters, to IEEE C62.69(TM)-2016. Test methods, test circuits, measurement procedures, and result treatment to determine the secondary winding resistance and saturated core inductance are given.