IEEE C62.92.3-1993 - IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part III - Generator Auxiliary Systems

IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part III - Generator Auxiliary Systems

Format
Availability
Price and currency
English PDF
Immediate download
143.27 EUR
Standard number:IEEE C62.92.3-1993
Released:03.06.1994
ISBN:978-0-7381-0934-3
Pages:30
Status:Active
Language:English
DESCRIPTION

IEEE C62.92.3-1993

This guide summarizes the general considerations in grounding of generating station auxiliary power systems and discusses the factors to be considered in selecting between the appropriate grounding classes and in specifying equipment ratings. This guide applies to both medium-voltage and low-voltage auxiliary power systems. Grounding and bonding to achieve practical safeguarding of persons is fulfillled by electrically connecting equipment frames and enclosures and interconnecting wiring raceways to the station grounding network (see IEEE Std 142-1991 1), as required by ANSI C2-1993. References to safety in this guide mean freedom from equipment damage. The emphasis is on reliability and availability of auxiliary system service achieved through control of ground-fault currents and transient overvoltages. This guide is specifically written for electrical utility systems and does not recognize the neutral grounding requirements for dispersed storage and generation. These requirements must recognize the restrictions imposed by the specific network to which the dispersed storage or generation is connected. Neutral grounding of dispersed storage and generation needs to be coordinated with the electrical utility system.

The purpose of this guide is to present some basic considerations for the selection of neutral grounding parameters that will provide for the control of ground-fault currents and overvoltage on auxiliary systems of electrical utility threephase generators.

New IEEE Standard - Superseded. Basic factors and general considerations in selecting the class and means of neutral grounding for electrical generating plant auxiliary power systems are given in this guide. Apparatus to be used to achieve the desired grounding are suggested, and methods to specify the grounding devices are given. Sensitivity and selectivity of equipment ground-fault protection as affected by selection of the neutral grounding device are discussed, with examples.