IEEE C62.92.3-2012 - IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part III -Generator Auxiliary Systems

IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part III -Generator Auxiliary Systems

Format
Availability
Price and currency
English PDF Redline
Immediate download
116.54 EUR
English PDF Redline
Immediate download
105.95 EUR
English PDF
Immediate download
82.33 EUR
English PDF
Immediate download
74.84 EUR
English Hardcopy
In stock
103.71 EUR
Withdraw:30.03.2023
Standard number:IEEE C62.92.3-2012
Released:22.02.2013
ISBN:978-0-7381-8080-9
Pages:36
Status:Active
Language:English
DESCRIPTION

IEEE C62.92.3-2012

The scope of this project is to summarize the general considerations in grounding of generating station auxiliary power systems, the factors to be considered in selecting between the appropriate grounding classes, and specifying equipment ratings. This guide applies to both medium-voltage (1 kV-15 kV) and low-voltage (less than 1 kV) auxiliary power systems. The intent of this guide is to discuss grounding methods which may be used to limit equipment damage. The emphasis is on reliability and availability of auxiliary power system service, achieved through control of ground-fault currents and transient overvoltages.

The purpose of this guide is to present some basic considerations for the selection of neutral grounding parameters that will provide for the control of ground-fault currents and overvoltage on auxiliary systems of electrical utility three-phase generators. The purpose of this revision is to update 5.3 with current research on equipment damage, update all references, and to ensure no intrusion or overlap with IEEE Std 1584™.

Revision Standard - Inactive-Reserved. Basic factors and general considerations in selecting the class and means of neutral grounding for electrical generating plant auxiliary power systems are given in this guide. Apparatus to be used to achieve the desired grounding are suggested, and methods to specify the grounding devices are given. Sensitivity and selectivity of equipment ground-fault protection as affected by selection of the neutral grounding device are discussed, with examples.