PRICES include / exclude VAT
Homepage>IEEE Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.280 Radiation protection>IEEE C95.1-2019 - IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz
Sponsored link
Released: 04.10.2019

IEEE C95.1-2019 - IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz

IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz

Format
Availability
Price and currency
English PDF Redline
Immediate download
370.33 EUR
English Hardcopy
In stock
341.17 EUR
Standard number:IEEE C95.1-2019
Released:04.10.2019
ISBN:978-1-5044-5549-7
Status:Active
Language:English
DESCRIPTION

IEEE C95.1-2019

This standard specifies exposure criteria and limits to protect against established adverse health effects in humans associated with exposure to electric, magnetic, and electromagnetic fields in the frequency range of 0 Hz to 300 GHz.1,2 These limits, incorporating safety margins, are expressed in terms of dosimetric reference limits (DRL) and exposure reference levels (ERL). DRLs are expressed in terms of in situ electric field strength, specific absorption rate (SAR), and epithelial power density. ERLs, which are more easily determined, are limits on external electric and magnetic fields, incident power density, induced and contact currents, and contact voltages intended to ensure that the DRLs are not exceeded. The limits, which protect against adverse health effects associated with electrostimulation of tissue and local and whole-body heating, are intended to apply to the described human exposure conditions. However, these levels are not intended to address exposures of patients or human research subjects under the care of medical professionals for which other risks and benefits might apply. These exposure limits might not prevent interference with medical and other devices that might exhibit susceptibility to electromagnetic interference (EMI).

The purpose of this standard is to provide science-based exposure criteria to protect against established adverse health effects in humans associated with exposure to electric, magnetic, and electromagnetic fields; induced and contact currents; and contact voltages, over the frequency range of 0 Hz to 300 GHz.

Revision Standard - Active. .Safety limits for the protection of persons against the established adverse health effects of exposures to electric, magnetic, and electromagnetic fields in the frequency range 0 Hz to 300 GHz are presented in this standard. These exposure limits are intended to apply generally to persons permitted in restricted environments and to the general public in unrestricted environments. These exposure limits are not intended to apply to the exposure of patients by or under the direction of physicians and medical professionals, as well as to the exposure of informed volunteers in medical or scientific research studies, and might not be protective with respect to the use of>medical devices or implants. (NOTE: As of June 29th 2022, Corrigenda 2 was appended to this standard. However, the individual Corrigenda can be downloaded at https://ieeexplore.ieee.org/document/9238523)