IEEE N42.12-1994 - American National Standard Calibration and Usage of Thallium-Activated Sodium Iodide Detector Systems for Assay of Radionuclides

American National Standard Calibration and Usage of Thallium-Activated Sodium Iodide Detector Systems for Assay of Radionuclides

Format
Availability
Price and currency
English PDF
Immediate download
128.30 EUR
English Hardcopy
In stock
147.55 EUR
Standard number:IEEE N42.12-1994
Released:26.01.1995
ISBN:978-0-7381-0738-7
Pages:20
Status:Active
Language:English
DESCRIPTION

IEEE N42.12-1994

This standard establishes methods for performance testing, calibration, and usage of thallium-activated sodium iodide [NaI(Tl)] detector systems for the measurement of gamma ray emission rates of radionuclides; the assay for radioactivity; and the determination of gamma ray energies and intensities. It covers both energy calibration and efficiency calibration. The following three techniques are considered: a) Total spectrum counting (see 4.1) employs a system that counts all pulses above a low-energy threshold (see 6.1, 6.2, and 6.3). b) Single-channel analyzer (SCA) counting (see 4.2) employs a system with a counting “window,” which establishes upper and lower energy boundaries (see 6.1, 6.2, and 6.3). c) Multichannel analyzer (MCA) counting (see 4.3) employs a system in which multiple counting windows are utilized. This technique allows measurements for which the continuum under the full energy peak may be subtracted without introducing unacceptable error. In case of overlapping peaks in the spectrum, it is realized that an MCA with access to a spectrum-stripping program is necessary. Such cases are not covered by this standard.

The purpose of this document is to provide a standardized basis for the calibration and usage of sodium iodide detector systems for the measurement of gamma ray emission rates of radionuclides. Typical applications include radionuclide identification and assay in various industrial, environmental, and medical applications. An NaI(Tl) detector system consists of three major components: a scintillating medium that produces a flash of light when ionizing radiation interacts with it; one or more photo multipliers, optically coupled to the scintillator, which converts the light flash to an amplified electrical impulse; and associated electronic instrumentation that powers the photomultiplier and processes the output signal. (See IEEE Std 398-1972. The theory of operation of NaI(Tl) detectors is presented in numerous publications, including [B3], [B5], and [B9] in clause 7

New IEEE Standard - Active. Methods for performance testing, calibration, and usage of NaI(Tl) detector systems for the measurement of gamma ray emission rates of radionuclides; the assay for radioactivity; and the determination of gamma ray energies and intensities are established. Both energy calibration and efficiency calibration are covered.