PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.220 Protection against fire>13.220.99 Other standards related to protection against fire>PD CEN/TS 12101-11:2022 Smoke and heat control systems Horizontal flow powered ventilation systems for enclosed car parks
Sponsored link
immediate downloadReleased: 2022-09-16
PD CEN/TS 12101-11:2022 Smoke and heat control systems Horizontal flow powered ventilation systems for enclosed car parks

PD CEN/TS 12101-11:2022

Smoke and heat control systems Horizontal flow powered ventilation systems for enclosed car parks

Format
Availability
Price and currency
English Secure PDF
Immediate download
370.26 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
37.03 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
111.08 EUR
English Hardcopy
In stock
370.26 EUR
Standard number:PD CEN/TS 12101-11:2022
Pages:54
Released:2022-09-16
ISBN:978 0 539 04923 7
Status:Standard
PD CEN/TS 12101-11:2022 Smoke and heat control systems Horizontal flow powered ventilation systems for enclosed car parks

PD CEN/TS 12101-11:2022 Smoke and Heat Control Systems

Horizontal Flow Powered Ventilation Systems for Enclosed Car Parks

Standard Number: PD CEN/TS 12101-11:2022

Pages: 54

Released: 2022-09-16

ISBN: 978 0 539 04923 7

Status: Standard

Overview

The PD CEN/TS 12101-11:2022 standard is an essential document for professionals involved in the design, installation, and maintenance of smoke and heat control systems, specifically focusing on horizontal flow powered ventilation systems for enclosed car parks. This comprehensive standard provides detailed guidelines and specifications to ensure the safety and efficiency of ventilation systems in enclosed parking facilities.

Key Features

  • Comprehensive Guidelines: This standard offers a thorough set of guidelines that cover all aspects of horizontal flow powered ventilation systems, ensuring that your car park ventilation system meets the highest safety and performance standards.
  • Up-to-Date Information: Released on 2022-09-16, this standard incorporates the latest advancements and best practices in the field of smoke and heat control systems.
  • Detailed Specifications: With 54 pages of in-depth information, this standard provides detailed specifications that are crucial for the proper design and implementation of ventilation systems in enclosed car parks.
  • ISBN: 978 0 539 04923 7, ensuring easy reference and cataloging for professionals and libraries.

Why Choose PD CEN/TS 12101-11:2022?

Ensuring the safety and efficiency of ventilation systems in enclosed car parks is of paramount importance. The PD CEN/TS 12101-11:2022 standard provides a reliable and authoritative source of information that helps professionals achieve this goal. By adhering to the guidelines and specifications outlined in this standard, you can be confident that your ventilation system will effectively control smoke and heat, enhancing the safety of the car park environment.

Applications

This standard is applicable to a wide range of professionals and industries, including:

  • Architects and Engineers: Ensuring that the design of enclosed car parks includes effective smoke and heat control systems.
  • Construction Companies: Implementing the guidelines during the construction phase to ensure compliance with safety standards.
  • Facility Managers: Maintaining and inspecting ventilation systems to ensure ongoing compliance and safety.
  • Regulatory Bodies: Using the standard as a benchmark for evaluating the safety and performance of ventilation systems in enclosed car parks.

Benefits

Adopting the PD CEN/TS 12101-11:2022 standard offers numerous benefits, including:

  • Enhanced Safety: By following the guidelines, you can significantly reduce the risk of smoke and heat-related incidents in enclosed car parks.
  • Regulatory Compliance: Ensure that your ventilation systems meet the latest regulatory requirements and industry standards.
  • Improved Efficiency: Optimize the performance of your ventilation systems, leading to better air quality and energy efficiency.
  • Professional Credibility: Demonstrate your commitment to safety and quality by adhering to a recognized and respected standard.

Conclusion

The PD CEN/TS 12101-11:2022 standard is an invaluable resource for anyone involved in the design, installation, and maintenance of smoke and heat control systems in enclosed car parks. With its comprehensive guidelines, up-to-date information, and detailed specifications, this standard ensures that your ventilation systems are safe, efficient, and compliant with the latest industry standards. Invest in the safety and performance of your car park ventilation systems by adopting the PD CEN/TS 12101-11:2022 standard today.

DESCRIPTION

PD CEN/TS 12101-11:2022


This standard PD CEN/TS 12101-11:2022 Smoke and heat control systems is classified in these ICS categories:
  • 13.220.99 Other standards related to protection against fire
This document gives minimum design, installation and commissioning requirements for powered smoke and heat control systems for enclosed car parks using horizontal flow powered ventilation, with or without sprinkler protection, on one or more levels, for cars and light commercial vehicles (max 3,5 t), to reach the design objectives outlined in this document . This document is applicable for car parks with vehicles powered by petrol, diesel, electricity, CNG or LPG. NOTE 1 For the purpose of this document for smoke ventilation systems, it is assumed that cars powered by electricity, CNG (compressed natural gas) or LPG (liquefied petroleum gas) will have similar HRR to vehicles powered by petrol or diesel. NOTE 2 Cars powered by hydrogen are not covered by this document. This document only covers traditional car parks that are with cars parked alongside each other, with common car access lanes. It does not cover other forms of car parking systems, such as stacking systems. This document does not cover requirements for day‐to‐day ventilation. Any other risks than fire from cars are not covered by this document.