PRICES include / exclude VAT
Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.140 Installations in buildings>91.140.50 Electricity supply systems>PD CLC/TR 50579:2012 Electricity metering equipment (A.C.). Severity levels, immunity requirements and test methods for conducted disturbances in the frequency range 2 kHz-150 kHz
Sponsored link
immediate downloadReleased: 2012-07-31
PD CLC/TR 50579:2012 Electricity metering equipment (A.C.). Severity levels, immunity requirements and test methods for conducted disturbances in the frequency range 2 kHz-150 kHz

PD CLC/TR 50579:2012

Electricity metering equipment (A.C.). Severity levels, immunity requirements and test methods for conducted disturbances in the frequency range 2 kHz-150 kHz

Format
Availability
Price and currency
English Secure PDF
Immediate download
191.18 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.12 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
57.35 EUR
English Hardcopy
In stock
191.18 EUR
Standard number:PD CLC/TR 50579:2012
Pages:16
Released:2012-07-31
ISBN:978 0 580 78265 7
Status:Standard
DESCRIPTION

PD CLC/TR 50579:2012


This standard PD CLC/TR 50579:2012 Electricity metering equipment (A.C.). Severity levels, immunity requirements and test methods for conducted disturbances in the frequency range 2 kHz-150 kHz is classified in these ICS categories:
  • 91.140.50 Electricity supply systems

This European Technical Report applies to newly manufactured static watt-hour meters intended for residential, commercial and light industrial use, of class indexes A, B and C, for the measurement of alternating current electrical active energy in 50 Hz networks. It specifies particular requirements and immunity test for direct connected and transformer connected electricity meters as an extension for EN 50470-1 and EN 50470-3. The tests are designed to achieve immunity against disturbing currents of up to 2 A (2 kHz-30 kHz) and up to 1 A (30 KHz-150 kHz) for direct connected meters and 2 % Imax (2 kHz-30 kHz) and 1 % Imax (30 KHz-150 kHz) for transformer connected meters.

It applies to static watt-hour meters for indoor and outdoor application, consisting of a measuring element and register(s) enclosed together in a meter case.

If the meter has (a) measuring element(s) for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces etc. are enclosed in the meter case (multi-function meters) then this Technical Report applies only for the active energy metering part.

This Technical Report distinguishes between:

  • meters of class indexes A, B and C;

  • direct connected and transformer operated meters;

It does not apply to:

  • watt-hour meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems);

  • portable meters;

  • reference meters.