PRICES include / exclude VAT
Homepage>BS Standards>11 HEALTH CARE TECHNOLOGY>11.040 Medical equipment>11.040.50 Radiographic equipment>PD IEC TR 60522-2:2020 Medical electrical equipment. Diagnostic X-rays Guidance and rationale on quality equivalent filtration and permanent filtration
Sponsored link
immediate downloadReleased: 2020-11-02
PD IEC TR 60522-2:2020 Medical electrical equipment. Diagnostic X-rays Guidance and rationale on quality equivalent filtration and permanent filtration

PD IEC TR 60522-2:2020

Medical electrical equipment. Diagnostic X-rays Guidance and rationale on quality equivalent filtration and permanent filtration

Format
Availability
Price and currency
English Secure PDF
Immediate download
309.60 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
30.96 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
92.88 EUR
English Hardcopy
In stock
309.60 EUR
Standard number:PD IEC TR 60522-2:2020
Pages:38
Released:2020-11-02
ISBN:978 0 539 00000 9
Status:Standard
PD IEC TR 60522-2:2020 - Medical Electrical Equipment

PD IEC TR 60522-2:2020 - Medical Electrical Equipment

Diagnostic X-rays Guidance and Rationale on Quality Equivalent Filtration and Permanent Filtration

Standard Number: PD IEC TR 60522-2:2020

Pages: 38

Released: November 2, 2020

ISBN: 978 0 539 00000 9

Status: Standard

Overview

The PD IEC TR 60522-2:2020 is a comprehensive standard that provides essential guidance and rationale on the quality equivalent filtration and permanent filtration in diagnostic X-ray equipment. This document is crucial for professionals in the medical field, particularly those involved in the operation and maintenance of medical electrical equipment. It ensures that the equipment meets the necessary safety and performance standards, thereby safeguarding both patients and healthcare providers.

Importance of Quality Equivalent Filtration

Quality equivalent filtration is a critical aspect of diagnostic X-ray equipment. It refers to the filtration that is equivalent in quality to the standard filtration required for specific diagnostic procedures. This standard provides detailed guidance on how to achieve the appropriate level of filtration, ensuring that the X-ray equipment operates efficiently and safely. Proper filtration is essential to minimize patient exposure to radiation while maintaining the quality of diagnostic images.

Permanent Filtration Explained

Permanent filtration is another key component addressed in this standard. It involves the use of fixed filters that are permanently installed in the X-ray equipment. These filters are designed to remove low-energy X-rays that do not contribute to image formation but increase patient dose. By adhering to the guidelines provided in this standard, healthcare facilities can ensure that their X-ray equipment is equipped with the necessary permanent filtration to protect patients and improve diagnostic accuracy.

Comprehensive Guidance for Healthcare Professionals

This standard is an invaluable resource for healthcare professionals, including radiologists, medical physicists, and biomedical engineers. It offers a thorough understanding of the principles and practices related to filtration in diagnostic X-ray equipment. By following the guidance outlined in this document, professionals can enhance the safety and effectiveness of their diagnostic procedures, ultimately leading to better patient outcomes.

Why Choose PD IEC TR 60522-2:2020?

  • Expert Guidance: Developed by leading experts in the field, this standard provides authoritative guidance on filtration in diagnostic X-ray equipment.
  • Enhanced Safety: By implementing the recommendations in this standard, healthcare facilities can significantly reduce patient exposure to unnecessary radiation.
  • Improved Diagnostic Accuracy: Proper filtration ensures high-quality diagnostic images, aiding in accurate diagnosis and treatment planning.
  • Compliance with International Standards: This standard aligns with international best practices, ensuring that your facility meets global safety and performance benchmarks.

Who Should Use This Standard?

The PD IEC TR 60522-2:2020 standard is designed for a wide range of professionals involved in the use and maintenance of diagnostic X-ray equipment, including:

  • Radiologists
  • Medical Physicists
  • Biomedical Engineers
  • Healthcare Facility Managers
  • Regulatory Compliance Officers

Conclusion

In the ever-evolving field of medical technology, staying updated with the latest standards is crucial for ensuring the safety and effectiveness of diagnostic procedures. The PD IEC TR 60522-2:2020 standard provides comprehensive guidance on quality equivalent filtration and permanent filtration in diagnostic X-ray equipment. By adhering to this standard, healthcare professionals can enhance patient safety, improve diagnostic accuracy, and ensure compliance with international best practices. Invest in this essential resource to elevate the quality of care in your facility.

DESCRIPTION

PD IEC TR 60522-2:2020


This standard PD IEC TR 60522-2:2020 Medical electrical equipment. Diagnostic X-rays is classified in these ICS categories:
  • 11.040.50 Radiographic equipment
IEC TR 60522-2:2020 provides guidance on quality equivalent filtration and permanent filtration with regards to the requirements of IEC 60522-1 and its modifications versus IEC 60522:1999.