PRICES include / exclude VAT
Homepage>BS Standards>29 ELECTRICAL ENGINEERING>29.200 Rectifiers. Convertors. Stabilized power supply>PD IEC/TS 62578:2015 Power electronics systems and equipment. Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz
Sponsored link
immediate downloadReleased: 2015-04-30
PD IEC/TS 62578:2015 Power electronics systems and equipment. Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz

PD IEC/TS 62578:2015

Power electronics systems and equipment. Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz

Format
Availability
Price and currency
English Secure PDF
Immediate download
399.30 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
39.93 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
119.79 EUR
English Hardcopy
In stock
399.30 EUR
Standard number:PD IEC/TS 62578:2015
Pages:114
Released:2015-04-30
ISBN:978 0 580 75477 7
Status:Standard
DESCRIPTION

PD IEC/TS 62578:2015


This standard PD IEC/TS 62578:2015 Power electronics systems and equipment. Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz is classified in these ICS categories:
  • 29.200 Rectifiers. Converters. Stabilized power supply

This Technical Specification IEC TS 62578 describes the operation conditions and typical characteristics of active infeed converters (AIC) of all technologies and topologies which can be connected between the electrical power supply network (lines) a.c. side and a constant current or voltage type d.c. side and which can convert electrical power (active and reactive) in both directions (generative or regenerative).

Applications with active infeed converters are commonly used with the d.c. sides of adjustable speed power drive systems (PDS), uninterruptible power systems (UPS), active filters, photovoltaic systems, wind turbine systems, battery backed power management systems etc. of all voltages and power ratings.

Active infeed converters are generally connected between the electrical power supply network (a.c. side) and a current or voltage d.c. side, with the objective to avoid emitting low frequency harmonics (e.g. less than 1 kHz) by synthesizing a sinusoidal a.c. current. Some of them can additionally compensate the pre-existing harmonic distortion of a given supply side voltage. They are moreover able to control the power factor of a power supply network section by moving the electrical power (active and reactive) in both directions (generative or regenerative), which enables energy saving in the system and stabilizes the power supply voltage or enables coupling of renewable energy sources or electrical energy storage devices to the supply.

A practical and analytical approach for emission values for AICs in power supply networks is given, which is based on the latest results for line impedance values between 2 kHz and 9 kHz and withstand capability of capacitors connected directly to the supply.

This results in design recommendations for emission values below 150 kHz.

The following is excluded from the scope.

  • Requirements for the design, development or further functionality of active infeed applications.

  • Probability of interactions or influences of the AIC with other equipment caused by parasitic elements in an installation or caused by poor electronic design as well as their mitigations.

  • "Overhead line" power supply networks because of lack of information (measurements) of their three phase impedances. This could be the subject for future editions.