PD IEC TS 62966-3:2021
Mechanical structures for electrical and electronic equipment. Aisle containment for it cabinets Aspects of operational and personal safety
Standard number: | PD IEC TS 62966-3:2021 |
Pages: | 24 |
Released: | 2021-02-09 |
ISBN: | 978 0 539 04932 9 |
Status: | Standard |
PD IEC TS 62966-3:2021 - Mechanical Structures for Electrical and Electronic Equipment
Aisle Containment for IT Cabinets: Aspects of Operational and Personal Safety
In the ever-evolving world of technology, ensuring the safety and efficiency of your IT infrastructure is paramount. The PD IEC TS 62966-3:2021 standard is a comprehensive guide that addresses the critical aspects of aisle containment for IT cabinets, focusing on both operational and personal safety. Released on February 9, 2021, this standard is an essential resource for professionals in the field of electrical and electronic equipment.
Key Features of the Standard
- Standard Number: PD IEC TS 62966-3:2021
- Pages: 24
- Release Date: 2021-02-09
- ISBN: 978 0 539 04932 9
- Status: Standard
Why This Standard is Essential
The PD IEC TS 62966-3:2021 standard is designed to provide a framework for the safe and efficient management of aisle containment systems in IT environments. Aisle containment is a critical component in data centers and other IT facilities, as it helps to optimize cooling efficiency, reduce energy consumption, and enhance the overall performance of IT equipment.
By adhering to this standard, organizations can ensure that their IT infrastructure is not only efficient but also safe for personnel. The standard outlines best practices for the design, installation, and maintenance of aisle containment systems, ensuring that they meet the highest safety and operational standards.
Operational Safety
Operational safety is a key focus of the PD IEC TS 62966-3:2021 standard. It provides guidelines for the safe operation of aisle containment systems, ensuring that they do not pose any risks to the equipment or the personnel working in the vicinity. The standard covers various aspects of operational safety, including:
- Proper installation and maintenance procedures
- Guidelines for monitoring and controlling environmental conditions
- Recommendations for emergency procedures and safety protocols
Personal Safety
In addition to operational safety, the standard also emphasizes the importance of personal safety. It provides detailed guidelines to ensure that personnel working in and around aisle containment systems are protected from potential hazards. Key aspects of personal safety covered in the standard include:
- Ergonomic considerations for personnel working in confined spaces
- Safety measures to prevent accidents and injuries
- Training and awareness programs for personnel
Benefits of Implementing the Standard
Implementing the PD IEC TS 62966-3:2021 standard offers numerous benefits for organizations, including:
- Enhanced Efficiency: By optimizing aisle containment systems, organizations can significantly improve the cooling efficiency of their IT infrastructure, leading to reduced energy consumption and cost savings.
- Improved Safety: The standard provides a comprehensive framework for ensuring the safety of both equipment and personnel, reducing the risk of accidents and equipment failures.
- Compliance: Adhering to the standard ensures that organizations meet industry best practices and regulatory requirements, enhancing their reputation and credibility.
Conclusion
The PD IEC TS 62966-3:2021 standard is an invaluable resource for any organization looking to optimize their IT infrastructure while ensuring the highest levels of safety and efficiency. With its comprehensive guidelines and best practices, this standard is a must-have for professionals in the field of electrical and electronic equipment.
Whether you are responsible for the design, installation, or maintenance of aisle containment systems, the PD IEC TS 62966-3:2021 standard provides the knowledge and tools you need to succeed. Invest in the safety and efficiency of your IT infrastructure today by implementing this essential standard.
PD IEC TS 62966-3:2021
This standard PD IEC TS 62966-3:2021 Mechanical structures for electrical and electronic equipment. Aisle containment for it cabinets is classified in these ICS categories:
- 31.240 Mechanical structures for electronic equipment
This part of IEC 62966 defines the requirements for operational and personal safety of aisle containments for IT cabinets.
The aim is to provide physical security for the IT equipment installed in the containment using the criteria “availability” and “safety”.
The requirements apply to all operational, working and maintenance procedures.
This document does not apply to ordinary persons, when using installations and equipment.
The requirements described herein are also intended to ensure that it is possible for authorized personnel to enter and remain in the containment (as accessible equipment) and to maintain or upgrade the systems installed in the containment without risk. It should also be possible to evacuate the containment quickly and safely at any time, especially in the event of a fire or any other hazardous situation, whilst reducing the health risk to personnel to a minimum.
Aspects relating to computing, data processing, data storage, building protection or the data centre itself do not fall within the scope of this document. Only those additional aspects arising from the integration of an aisle containment are considered.
The design and positioning of an aisle containment, which is integrated in the data centre, has influence on the following different aspects of operational safety:
escape and evacuation plans;
escape routes;
emergency exits;
functional aspects of escape doors;
lighting conditions
lighting and signposting of escape routes;
fire protection.
In this document, these operational safety requirements and recommendations are considered.
To achieve the highest effectiveness, all these requirements are considered as much as possible during the design of an aisle containment.
This document applies to normal operations, not to the initial installation of the containment.