PRICES include / exclude VAT
Homepage>BS Standards>17 METROLOGY AND MEASUREMENT. PHYSICAL PHENOMENA>17.140 Acoustics and acoustic measurements>17.140.50 Electroacoustics>PD IEC TS 63070:2019 Ultrasonics. Field characterization. Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air
Sponsored link
immediate downloadReleased: 2019-02-19
PD IEC TS 63070:2019 Ultrasonics. Field characterization. Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air

PD IEC TS 63070:2019

Ultrasonics. Field characterization. Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air

Format
Availability
Price and currency
English Secure PDF
Immediate download
249.60 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
24.96 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
74.88 EUR
English Hardcopy
In stock
249.60 EUR
Standard number:PD IEC TS 63070:2019
Pages:30
Released:2019-02-19
ISBN:978 0 580 96640 8
Status:Standard
DESCRIPTION

PD IEC TS 63070:2019


This standard PD IEC TS 63070:2019 Ultrasonics. Field characterization. Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air is classified in these ICS categories:
  • 17.140.50 Electroacoustics

This document is applicable to ultrasonic equipment designed for the medical field of application. It covers both diagnostic and therapeutic (physiotherapy and HITU) equipment.

This document describes transducer evaluation by the infrared imaging technique using a split TMM-phantom for qualitative and quantitative estimation of temperature distributions in tissue-mimicking material, resulting from absorption of ultrasound and from heating of the transducer itself.

This document also describes a method to measure transducer-surface temperature, while the transducer is driven under the still-air condition.

NOTE 1 When the transducer is in contact with tissue-mimicking material, the heating of the transducer itself depends on the actual efficiency of the transducer, on the specific conditions for thermal transfer to or from the tissue-mimicking material, and on the transmitting/receiving electronic circuits, such as a switching circuit or pre-amplifier in some cases.

NOTE 2 The test objects specified in this document are for the measurement of temperature rise and not for the determination of thermal index, which is, by definition in IEC 62359:2010 and IEC 62359:2010/AMD1:2017, an algebraic combination of acoustical field quantities and therefore is not a physically measurable quantity.